Vehicle Loop Detector for Gate

> Output relays: 240V/5A

> Reaction time: 10ms

> Size of Housing: L78 x W40 x H108mm

  • Brand:

    S4A
  • Item NO.:

    PD-132
  • Specifications
  • Package

Vehicle Loop Detector for gate

Model No.: PD-132


PD-132 Inductive Vehicle Single Loop Detector for Automatic Gate opener barrier gate Traffic Inductive Vehicle access

Leave a message to us, if you need DC12V/DC24V/AC110V,no message send AC220V


Install Detector

The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as “Loop installation guide”).


Supply voltage

230V AC, 115V AC, 24V DC/AC, 12V DC/AC (See the label on the detector)

Voltage tolerance AC

+10%/-15%

Voltage tolerance DC

±15%

Power Consumption

4.5VA

Output relays

240V/5A

Operating temperature

-20℃ ~ 65℃

Storage temperature

-40℃ ~ 85℃

Frequency range

20 KHz ~ 170 KHz

Reaction time

10ms

Signal holding time

Unlimited / limited when loop is permanently covered 10 minutes

Sensitivity

Adjustable in 4 increments

Loop inductance

Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH

Loop connection wiring

Maximum length 20 meters, twisted at least 20 times per meter

Size of Housing

L78 x W40 x H108mm

Vehicle Loop Detector


Operation and Indication

While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate.The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered.


Frequency

To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.


Sensitivity

The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.


Automatic Sensitivity Boost

Automatic sensitivity boost is selected by DIP5 switch on the front of the enclosure and is set

as follows: OFF - Disabled, ON – Enabled.

Automatic sensitivity boost causes the sensitivity to be boosted to a maximum on detection

on the vehicle, and maintained at this level during the presence of the vehicle over the loop. When

the vehicle departs the loop and detection is lost the sensitivity reverts to the pre-selected level.

Vehicle Loop Detector

Filter

To eliminate interference of the bad environment, the filter mode is activated by setting the DIP6 Switch to “ON” site. In this mode, the reaction time of the detector is delayed, and the sensitivity is reduced. Usually, the filter mode is disabled by setting the DIP6 Switch to “OFF” site.

【Attention】 If the detector isn’t working normally, you must check the loop and wiring at first, and then alter the frequency or the sensitivity. At last, try to set it to filter mode.

 

Output Relay

If DIP7 is “OFF” site, when a vehicle is detected passing over the inductive loop, the relay1 and relay2 are energized; When the vehicle is detected departing the loop, the relay1 and relay2 are de-energized.If DIP7 is “ON” site, when a vehicle is detected passing over the loop, the relay2 is energized;When the vehicle is detected departing the loop, relay2 is de-energized , and delay 500 ms, the relay1 is energized for 500 ms.

 

Presence Time

The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is

configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence

 

Reset Switch

The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to retune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.


Vehicle Loop DetectorVehicle Loop DetectorVehicle Loop Detector


Vehicle Loop Detector for Gate

Model No.

Quantity/Carton

Gross Weight

Carton Size

PD-132

100pcs

29.4KG

44X27X51 CM


Vehicle Loop Detector

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
Pressure wave switch sensors
Pressure wave switch sensors for traffic Barrier and Door Systems

>Rated voltage:5- 250v>Wiring:Wiring connection (with terminal block)>Rated current:5- 20mA>Interface:Outer diameter 3mm direct plug interface>Work pressure:2- 5mpa>Electrical properties:Up to 100mA/250VAC

1m long range rfid reader
1m Uhf Long Range Rfid Reader

> Card reading distance: 0~3M> Output Interface: WG26,WG34,RS485> Operating Voltage: DC12V 80MA> Size: 121x78x22mm

Uhf Rfid Reader
Uhf Rfid Reader 1-5m Long Range Outdoor Ip67 8dbi Antenna Rs232/rs485/wiegand Output Uhf Rfid Reader

> Waterproof, IP65> Free demo and SDK> Stable reading distance: 1~5m> Frequency: 902~928MHz or customize other frequency

UHF RFID Passive Reader
Uhf Rfid Passive Reader with 915m Long Distance Access Control Vehicle Logistics Application

> Waterproof, IP65> Free demo and SDK> Stable reading distance: 5~15m> Frequency: 920-925MHz or customize other frequency

UHF RFID USB Desktop Reader
UHF RFID USB Desktop Reader Only with Keyboard Emulation Output

> 860~868MHz, 902~928MHz frequency band(frequency customization optional)> Built-in antenna with effect distance up to 200mm*> Support USB2.0 interface with VSP(Virtual Serial Port) or HID mode

Usb To Rs232 Converter Cable
Usb To Rs232 Converter Cable 0.8M

> Cable Length: 0.8M> USB port: Support USB 1.1 / 1.0 / 2.0> Chips: CH-340

Loop Detectors
Double Channesl Vehicle Loop Detectors for Parking Lots

> Output relays: 230V AC, 115V AC, 24V DC/AC, 12V DC/AC (See the label on the detector)> Reaction time: 100ms> Size of Housing: L78 x W40 x H108mm

Single Vehicle Detector
Single Way Vehicle Door Detector

> Power supply: AC220V,AC110V,DC12V,DC24V> Sensitivity: 3 levels adjustable (low, medium, high)> Reaction time: 35ms> Working frequency: One-level adjustable> Size: 112x73x38mm> Delay function: Three-stage delay adjustable (1st gear 0.7s)