Foot witch automatic door are often used in hospitals and are commonly used in hospital operating rooms. This type of automatic door is very convenient to use, but it is also prone to various problems. As an automatic door after-sales maintenance company, the doorway often repairs this type of door type. Today, we summarized some common failures of the footswitch automatic door in the hospital operating room. The door repair method is hoped to be helpful to customers who use this door type.
Repair method of footswitch automatic door failure in hospital operating room
Fault 1: The automatic door of the hospital operating room cannot be opened by the footswitch.
Repair method: first check the circuit to see if the motor and foot sensor switch is connected to the power supply. If so, you need to confirm whether there is any problem with the controller and switch. If there is no problem, it is recommended to contact the doorway and let the repairer come to check it.
Fault 2: The automatic door of the hospital operating room is turned on and off by foot. It opens after power on and automatically closes when the foot is turned on. The control is chaotic.
Maintenance method: In this case, the footswitch and automatic door controller of the hospital operating room should be adjusted in the opposite direction.
Trouble 3: The footswitch of the automatic door switch in the hospital operating room is malfunctioning.
Repair method: first check whether it is due to line problems, such as line problems, just reconnect. After checking whether the footswitch is damaged, replace and repair it.
Fault 4: After the automatic door of the foot switch in the operating room of the hospital is powered on, the door remains open and does not close.
Repair method:
1. Check whether the red indicator light of the safety light-receiving box is always on. If the green indicator light is flashing, the two black plug wires on the safety light-receiving box need to be swapped in position. If the red indicator light is always on, you need to adjust the marked position of the controller. If the current white switch is at the "R" position, you need to adjust it to the "L" position and restart the power switch to test whether it is normal.
2. After restarting the power supply, if the door is still open and not closed, check the controller, "DRP" shows the lighted state, which means there is a door open signal. Check whether the wiring of the footswitch on the right side of the track is correct. Plug and unplug the footswitch wiring socket (possibly poor contact). If it still fails, you need to replace the footswitch.